AquaVENT® heated and humidified breathing circuits can be customised for both CPAP or High Flow, helping reduce clinical waste and streamline delivery of care.
Continuous Positive Airway Pressure (CPAP) is delivered to correct hypoxia. Indications include cardiogenic pulmonary oedema and atelectasis.
CPAP recruits collapsed alveoli and improves gas exchange by:
Application of PEEP (Positive End Expiratory Pressure) valve to maintain expiratory pressure.
Delivering flow to meet the patients peak inspiratory requirements and maintain PAP.
Delivery of CPAP is confirmed via pressure manometer.
AquaVENT® Transition System
One System
Two Therapies
Greater Efficiencies
The AquaVENT® Transition System comprises of a HFOT breathing circuit and a CPAP Transition Kit that allows for up to 7-day single patient use. Its ability to transition between therapies prioritises patient well-being and helps you streamline delivery of care.
High flow oxygen therapy delivered through AquaNASE® nasal cannula provides heated and humidified gases at flows up to 80 L/min.
Improved patient comfort
Reduced oxygen dilution
Dead space washout
Improved secretion clearance
Variable PEEP
Streamlined Delivery of Care
Play Video
Clariti PEEP Valves
Positive End Expiratory Pressure (PEEP) is used to maintain pressure on the lower airways at the end of the breathing cycle which prevents the alveoli from collapsing during expiration. Clariti PEEP valves are fixed value colour coded valves made from a transparent material which allows monitoring of the patient’s respiratory rate and blockage assessment while a highly fluorescent valve facilitates observation of valve functionality.
Transparent casing enables monitoring of patient’s respiratory rate and blockage assessment
Fluorescent valves facilitate the observation of valve functionality
Available in 7 colour coded sizes
Available as part of CPAP kits, including face mask, headgear and circuit
Flowkit Customisation
Enabling easy transition between CPAP and HFOT facilitating easy transition it allows breaks for food, visits and oral hygiene. It minimises waste by providing all you need to deliver CPAP and HFOT in one circuit. It is protected by BioCote®, an antimicrobial silver additive to limit the number on the surface of the breathing circuit and protecting it from microbial colonisation.
Play Video
CPAP – Components
A range of CPAP components are available for use with our CPAP face masks, headgear and breathing systems. Components can be assembled to your requirements or purchased separately.
Product Codes
Code
Description
Box Quantity
CPAP Breathing Circuit Product Codes
AMCPUK01258
CPAP adapter limb (FD140)
20
AMCP1409-032
CPAP adapter limb (POINT system)
20
Flowkit Customisation Product Codes
AMVC1792-004
Ventilator circuit, adult, single limb, heated for use with 850 series heater humidifier, length 1.5m in smooth bore tubing with C02 exhalation valve (KOEV valve) with tubing and 0.2µm hydrophobic gas filter with humidification limb length 0.8m in corrugated tubing with auto-fill humidification chamber with bacterial viral breathing filter.
20
AMVC1792-113
Ventilator circuit, adult, single limb, heated for use with 850 heater humidifier, length 1.6m in standard corrugated tubing with manometer tubing and 0.2µm hydrophobic gas filter with vented Bi-Level face mask SMALL and headgear with humidification limb length 0.8m in standard corrugated tubing with auto-fill humidification chamber with bacterial viral breathing filter with CO2 exhalation valve (KOEV valve) bagged separately.
10
AMCP1409-003
AquaVENT® CPAP limb, adult, heated for use with ‘850’ series heater humidifiers, length 1.6m and auto-fill humidification chamber with humidification limb length 0.6m in standard corrugation tubing.
20
AMHO1509-008
AquaVENT® Humidified Oxygen System, adult, heated for use with ‘850’ series heater humidifiers length 1.5m with humidification limb, auto-fill humidification chamber with AquaNASE® Nasal High Flow System, size MEDIUM (5mm).
20
AMCPUK01243
AquaVENT® CPAP System, adult, single limb heated for use with ‘850’ series heater humidifiers, length 1.5m with heated inspiratory limb with 0.45m humidification limb with manometer line assembly with auto-fill humidification chamber with safety valve.
10
AMCPUK01241
AquaVENT® CPAP System, adult, single limb heated for use with ‘850’ series heater humidifiers, length 1.5m with heated inspiratory limb with 0.9m humidification limb with manometer line assembly with 5cm patient PEEP valve with auto-fill humidification chamber with safety valve.
10
AMVC1792-004
Ventilator circuit, adult, single limb, heated for use with 850 series heater humidifier, length 1.5m in smooth bore tubing with C02 exhalation valve (KOEV valve) with tubing and 0.2µm hydrophobic gas filter with humidification limb length 0.8m in corrugated tubing with auto-fill humidification chamber with bacterial viral breathing filter.
20
AMVC1792-013
Ventilator circuit, single limb, adult, non-heated, length 1.8m in smooth bore PE tubing with CO2 exhalation port and bacterial viral breathing filter.
20
AMCA1402-6
Adult, 1.8m length single limb circuit in smooth bore PU tubing 22mmØ.
25
AMVC1792-092
Ventilator circuit, single limb, adult, non-heated, length 1.8m in smooth bore PE tubing with bacterial viral breathing filter.
20
AMVC1792-016
Ventilator circuit, adult, single limb, non-heated, length 1.8m in smooth bore tubing with exhalation valve with double swivel plain patient elbow with bacterial viral breathing filter with supplemental oxygen tubing.