NeoFlow Ventilator Circuits
Key Details
NeoFlow Ventilator Circuits with AquaVENT® VT technology provide optimal humidity and a dry expiratory limb.
Features
- Adapters to fit common ventilators
- Nitric oxide connectors
- Autofill humidification chamber with 1.2m feedline
- Protected by Biocote®
- Tubing clips
- 1.3m Inspiratory limb with 1.2m heated section
- Swivel-Y Piece
- Available with NEO VT technology or unheated with water trap
AquaVENT® Heater Humidifier
The AquaVENT® Heater Humidifier maintains consistent heat to the breathing circuit even at low tidal volumes, delivering optimal humidity to infants who require respiratory support via an endotracheal tube, nCPAP generator or High Flow Nasal Cannula.
Read more about our AquaVENT® Heater Humidifier.
Optimal Humidity, Minimal Condensate
Optimal humidity is necessary in the management of invasively ventilated infants. With active humidification systems, water in the expiratory limb is a common problem. NeoFlow ventilator circuits with AquaVENT® VT provides a solution to this problem.
The unique layered properties of the expiratory limb achieves a high Moisture Vapour Transition Rate (MVTR), providing a dry expiratory limb.
For more information on reducing condensation, read our Humidity Management Flyer.
BioCote® Antimicrobial Protection
BioCote® antimicrobial silver additive limits the number of microbes on the surface of the ventilator circuit, protecting it from microbial colonisation.
Neonatal Swivel-Y
Our Swivel-Y piece has 3-point independent rotation & combined articulation, enabling smooth movement when maintaining a fixed endotracheal tube.
Product Codes
AquaVENT® NEO VT Ventilation Circuits
Dual heated limb circuit for SLE 4000, 5000, and 6000 with NEO VT
Code Type | Code |
---|---|
Product Code | AMVC1775-203 |
Box Quantity: 20
AquaVENT® NEO VT Ventilation Circuits
Dual heated limb circuit for Drager/Fabian (and similar) with NEO VT
Code Type | Code |
---|---|
Product Code | AMVC1775-204 |
Box Quantity: 20
AquaVENT® NEO Ventilation Circuits
Dual heated limb circuit for inspiratory flow <4lpm
Code Type | Code |
---|---|
Product Code | AMVC1775-162 |
Box Quantity: 20
AquaVENT® NEO Ventilation Circuits
Dual heated limb circuit for HFOV
Code Type | Code |
---|---|
Product Code | AMVC1775-175 |
Box Quantity: 20
AquaVENT® NEO Ventilation Circuits
Single heated limb circuit for invasive ventilation
Code Type | Code |
---|---|
Product Code | AMVC1774-157 |
Box Quantity: 20
Downloads
Product Literature
File | Type | Size | Date |
---|---|---|---|
![]() AM NeoFlow Brochure v2.2 |
13.16 MB | 22nd Jul 2019 | |
![]() Breathing-Systems-Catalogue-v2 |
4.82 MB | 27th Jan 2021 | |
![]() Neonatal Humidity Management |
1.56 MB | 23rd Jul 2019 |
Guidance For Use
File | Type | Size | Date |
---|---|---|---|
![]() AM NeoFlow Invasive Ventilation GFU UK |
670.42 KB | 23rd Jul 2019 |